SAP Note 1032816 - PERFORM_CONFLICT_TAB_TYPE when loading to write-opt. DataStr

Component : Persistent Staging Area -

Solution : https://service.sap.com/sap/support/notes/1032816 (SAP Service marketplace login required)

Summary :
Runtime errors such as PERFORM_CONFLICT_TAB_TYPE and OBJECTS_TABLES_NOT_COMPATIBLE are reported in SAP NetWeaver 2004s BI when data is uploaded via InfoPackage to a write-optimized DataStore without a DTP, particularly after updates in both the write-optimized DataStore and the PSA. Similarly, from the second data package onwards, errors occur in PSA writing processes such as RSAR 130 and RSM2 851. These issues are due to programming errors. The mitigation involves importing Support Package 13 for SAP NetWeaver 2004s BI (SAPKW70013). In urgent cases, preliminary corrections can be implemented ahead of the support package release, with reactivation of DataSource if issues persist.

Key words :
solution sap netweaver 2004s bi            import support package 13, symptom runtime error perform_conflict_tab_type occurs, sap netweaver 2004s bi, runtime error objects_tables_not_compatible occurs, data transfer process dtp, runtime error occurs, data transfer process, composite sap note, sap note assistant, write-optimized datastore

Related Notes :

1011773SAPBINews NW BI 7.10 ABAP SP01