SAP Note 1052146 - BIA 7.00/7.20: Use of merge for delta index by memwatch

Component : TREX BI Accelerator - BW Accelerator

Solution : https://service.sap.com/sap/support/notes/1052146 (SAP Service marketplace login required)

Summary :
This SAP Note addresses inconsistencies in document indexing checks within the Business Warehouse Accelerator context. The primary cause is identified as simultaneous memwatcher-triggered merges of disk delta indexes during inspections. For BWA700, the resolution involves setting "merge_deltas = no" in the TREXIndexServer.ini file under the [memwatch] section to disable automatic merges. For BWA 7.20, configurations differ based on usage scenarios: BW+BWA720 and ESH+BWA720, both requiring "merge_deltas = yes" but handling merge operations differently. It's essential to restart the index servers after these changes to implement the settings effectively.

Key words :
merging normal disk delta indexes, guarentee bwa 720 working properly, disk delta index, terms bi accelerator, bw+bwa720 scenario, memory delta index, automatic merge functionality, esh+bwa720 scenario, delta indexes, delta index

Related Notes :

1044015Check whether all data has arrived in the BIA