Diagnosis Start meter reading missing for the selected meter and period. Procedure Interpretation of the measurement documents for the service chargesettlement with fix unit prices in Japan:
- The first measurement document defined for a day shows the final meter
reading on the day before the date of the measurement document.
- Additional measurement documents defined for a day show the meter
readings on the day of the measurement documents. Example: For a meter, there are the following measurement documents:
- 31.12.2005,, 0,000,,kWh,,( shows the consumption till 30.12.2005 )
- 31.01.2006,,1000,000,,kWh,,( shows the consumption between 31.12.2005 -
30.01.2006 )
- 28.02.2006,,1000,000,,kWh,,( shows the consumption between 31.01.2006 -
27.02.2006 ) For the period 01.01.2006 - 31.01.2006, the consumption will be in thiscase: 1003 kWh. ( 30 day * 1000 kWh / 31 day + 1 day * 1000 kWh / 28 day = 1003 kWh )
|