Diagnosis
Example: Base unit of measure is kg and the sample unit of measure is gr. Theconversion factor is 1000. The factor of the sample unit is 5. As aresult the individual sample is 5 grams. If the lot size is, for example, 20 kg, then the population to whichthe sampling scheme is applied is 4000 (20 * 1000 / 5). If thecalculated population exceeds the maximum allowed value of10,000,000,000, the maximum value is used if it is entered in the "Lotsize" column in the sampling scheme. Procedure |