SAP Message BRAIN860 - Metadata for InfoObject &1 is inconsistent

Diagnosis
The metadata for this characteristic is inconsistent. Table &V2& is notgeneric; a master data read class must therefore be entered for thischaracteristic.
A master data read class should be specified for each of the followingcharacteristics:

  • 0CALMONTH

  • 0CALMONTH2

  • 0CALQUART1

  • 0CALQUARTER

  • 0CALWEEK

  • 0CALYEAR

  • 0CURRENCY

  • 0FISCPER

  • 0FISCPER3

  • 0FISCVARNT

  • 0FISCYEAR

  • 0LOGSYS

  • 0SOURSYSTEM

  • 0UNIT

  • 0WEEKDAY1

  • 0RATE_TYPE

  • 0DATE

  • 0LANGU

  • These technical characteristics and time characteristics wereredelivered with new properties in SAP NetWeaver 2004s. The technicalContent is activated when the Data Warehousing Workbench is started forthe first time. If the (time) characteristic already exists in theactive version, it is not reinstalled from the technical Content.

    Procedure

    • If the active version of the characteristic does not contain master
    • data, reinstall the characteristic from the Content. If required,compare the data. Ensure that the With Master Data property isselected.
      • The characteristic does not have a generated table; it has a separate,
      • delivered table (for example, unit 0CURRENCY -> table TCURC). Acorresponding master data read class must be specified in thecharacteristic definition (for example, for unit 0CURRENCY -> classCL_RSMD_RS_0CURRENCY). A master data read class is saved automaticallyby XPRA RSDG_XPRA_IOBJ_TO_NW05. This XPRA is executed when you performan upgrade. However, it is possible that this XPRA cannot be executedsuccessfully. If the XPRA is not executed successfully, you can restartit manually.
        ,,Start transaction SE38.
        ,,In the Program field, enter RSDG_XPRA_IOBJ_TO_NW05.
        ,,Choose Execute to execute the program.