Diagnosis A volume correction factor procedure that requires calculation ofcompressibility and/or supercompressibility through user exit EXIT_SAPLEA54_001> is active for the specified register. In thiscase, however, the value could not be calculated because return tabley_table_compr_factors has an incorrect structure. The interval passedon by parameters X_DATE_FROM and X_DATE_TO is not completely covered bydiscontinuous table entries in return table y_table_compr_factors.Procedure First analyze the cause of the termination in your user-defined userexit. Inform the person who is responsible for programming the userexit. The person responsible for the program should note the following: In the IS-U menu, choose Billing execution> -> Billinganalysis>. Choose Settings> -> General>, then set the Debugging on > indicator. Start a billing simulation with the affected contract. Enter TGHUEXITin the Breakpoint at> field. You branch immediately to the point where your user exit is called, andyou may be able to localize the error in debugging. |