SAP Message AH689 - Routine &1 include &2: parameter &3 not specified

Diagnosis
During conversion of units of measurement in a dimension, the systemestablished that not all required units of measurement have beenspecified.

System Response
Processing is canceled.

Procedure
Check whether one of the following causes applies:
The units of measurement for meter reading and for billing need to bespecified.
If gas billing is to occur, the units of measurement in the volumecorrection factor procedure and the calorific value procedure also needto be maintained. In each of these procedures the following units ofmeasurement should be the same, or at least fall within the samedimensions.
Unit of measurement for meter reading and unit of measurement beforeconversion of volume correction factor (such as M3)
Unit of measurment after conversion of volume correction factor andunit of measurement before conversion of calorific value (such as NM3)
Unit of measurement after conversion of calorific value and unit ofmeasurement for billing (such as KWh)
If you do not find any errors here, the problem could be due to aninternal error. If this is the case, contact SAP.