Diagnosis The entered &v1& number must conform to a module 19 check. The MODULUS 19 Check is used to confirm the validity of the ECON/SCONprovided by the Employer. It cannot identify if any of the digits of thereference number provided are incorrect therefore it shuld not be usedto amend the reference number in an attempt to provide the correctSCON/ECON. The calculation used to confirm the validity of the supplied SCON/ECONis as follows .- FIXED VALUE FOR A SCON = 51 FIXED VALUE FOR AN ECON = 37 Example To confirm the validity of SCON S1301234T, take the supplied digits ofthe reference number and multipy as follows 1 x 8 = 8 3 x 7 = 21 0 x 6 = 0 1 x 5 = 5 2 x 4 = 8 3 x 3 = 9 4 x 2 = 8 Total = 59 Total + Fixed Value(51) = 110 DIVIDE 110 by 19 = 5 remainder 15 The remainder is then checked against a table of check letters toconfirm that the check letter is 'T'. Procedure Correct the entered number |