| RMXTDIA065 |
F1 help is not available for this field |
| RMXTDIA066 |
Assign a Trial Management class to Recipe Management class &1 |
| RMXTDIA067 |
No value was passed for import parameter &1 |
| RMXTDIA070 |
Select a row |
| RMXTDIA071 |
No form exists for report &3 in language &1 and client &2 |
| RMXTDIA072 |
Select a cell in the 'Stock Batch' column |
| RMXTDIA080 |
Enter an actual quantity |
| RMXTDIA081 |
Batch &1 is already being used in a process order |
| RMXTDIA090 |
Enter a valid stability study building block |
| RMXTDIA091 |
Change the product hierarchy assignment |
| RMXTDIA092 |
Trial does not have a stability study building block |
| RMXTDIA093 |
Specify a valid trial |
| RMXTDIA094 |
Trial does not have any subordinate trials |
| RMXTDIA095 |
Trial &1 does not exist |
| RMXTDIA096 |
Trial &1 is assigned to a different plant (&2) |
| RMXTDIA097 |
No data is available for the building block summary |
| RMXTDIA200 |
Inspection characteristic was selected already |
| RMXTDIA201 |
You are not permitted to delete planned inspection characteristics |
| RMXTDIA202 |
Right-click to select an inspection characteristic |
| RMXTDIA203 |
Master inspection characteristic does not exist |
| RMXTDIA204 |
Right-click to select an inspection operation |
| RMXTDIA205 |
Cannot insert unplanned inspection characteristic |
| RMXTDIA206 |
You are not authorized to change the inspection specifications |
| RMXTDIA207 |
You can only select inspection characteristics from one inspection plan |
| RMXTDIA208 |
Insp. characteristic &1 for version &2 does not exist in insp. plan &3 |
| RMXTDIA209 |
Insp. charac. &1 with version &2 will be deleted from trial when you save |
| RMXTDIA210 |
Unplanned charac. &1, version &2: Related operation missing in plan &3 |
| RMXTDIA211 |
You can no longer use deleted plan characteristics |
| RMXTDIA220 |
No inspection plan found for task list usage &1 |
| RMXTDIA600 |
Search criteria were corrected |
| RMXTDIA601 |
No data found |
| RMXTDIA602 |
Select at least one entry from the hit list |
| RMXTDIA700 |
Trial view &1 is using obsolete functions; see SAP Note 787395 |
| RMXTDIA801 |
File &1 could not be opened |
| RMXTDIA802 |
File does not refer to trial &2 |
| RMXTDIA803 |
Invalid file format |
| RMXTDIA804 |
XML file &1 was read |
| RMXTPP000 |
**************************** Trial Planning ***************************** |
| RMXTPP001 |
Planning was not started |
| RMXTPP002 |
Plant &1 does not exist |
| RMXTPP003 |
Planned order data is incomplete |
| RMXTPP004 |
Trial type &1 is not assigned a transformation group |
| RMXTPP005 |
Trial &1 is not assigned a planned order |
| RMXTPP007 |
No master recipe is assigned to the trial |
| RMXTPP008 |
Planned order &2 is assigned to trial &1 |
| RMXTPP009 |
Date &1 is not within the planning period |
| RMXTPP010 |
No process order is assigned to the trial &1 |
| RMXTPP011 |
Process order &2 is assigned to trial &1 |
| RMXTPP012 |
Trial &1 does not have a lower-level trial |
| RMXTPP013 |
Planning level for trial &1 is not unique |
| RMXTPP014 |
No planned orders are defined for the type of trial &1 |
| RMXTPP015 |
No planned order created for trial &1 |
| RMXTPP016 |
Trial &1 and the lower-level trial &2 are inconsistent |
| RMXTPP017 |
Data is incomplete for the explosion of trial &1 |
| RMXTPP018 |
Planned orders are not permitted for trial type &1 |
| RMXTPP019 |
Planning for trial &1 was not exploded completely |
| RMXTPP020 |
Planning for trial &1 was exploded completely |
| RMXTPP021 |
Error while checking the planned orders for trial &1 |
| RMXTPP022 |
Planned order &1 for trial &2 was deleted |
| RMXTPP023 |
No recipe is assigned to trial &1 |
| RMXTPP024 |
Master recipe &2 from recipe group &3 is assigned to trial &1 |
| RMXTPP025 |
PP control parameters are not available for plant &1 |
| RMXTPP026 |
Create the planned order profile and order type |
| RMXTPP027 |
No PP-PI objects are assigned to trial &1 |
| RMXTPP028 |
No generated PP-PI objects are assigned to trial &1 |
| RMXTPP029 |
Production version &1 for material &2 in trial &3 was deleted |
| RMXTPP030 |
Background process could not be started |
| RMXTPP031 |
No task from class &1 exists in the current task group &2 |
| RMXTPP032 |
Process orders are not permitted for trial type &1 |
| RMXTPP033 |
Process orders are permitted for the lowest hierarchy level only |
| RMXTPP034 |
No process order created for trial &1 |
| RMXTPP035 |
No recipe transformation is carried out for trial &1 |
| RMXTPP036 |
Generation of process orders is incomplete for trial &1 |
| RMXTPP037 |
Generation of process orders is complete for trial &1 |
| RMXTPP038 |
Background job for trial &1 was deleted |
| RMXTPP039 |
Background job for trial &1 was not released |
| RMXTPP040 |
Task &1 started for trial &2 |
| RMXTPP041 |
Trial &1 is planned |
| RMXTPP042 |
Task &1 for trial &2 ended with errors |
| RMXTPP043 |
Task &1 for trial &2 ended without errors |
| RMXTPP044 |
Status &1 (&2) was set |
| RMXTPP045 |
Status &1 (&2) was not set |
| RMXTPP046 |
Status &1 (&2) was reset |
| RMXTPP047 |
Status &1 (&2) was not reset |
| RMXTPP048 |
Trial &1 does not have status &2 (&3) |
| RMXTPP049 |
Background jobs are not available for trial &1 |
| RMXTPP050 |
Error during the selection of background jobs |
| RMXTPP051 |
Some background jobs for trial &1 are not finished |
| RMXTPP052 |
Resource &1 is not considered in the current planning |
| RMXTPP053 |
Internal error while displaying background jobs |
| RMXTPP054 |
Trial &1 is being processed in the background |
| RMXTPP055 |
PP control parameters are not available for plant &1, trial type &2 |
| RMXTPP056 |
Planned date is not available for trial &1 |
| RMXTPP057 |
Trial-type-independent PP control parameters not available for plant &1 |
| RMXTPP058 |
Internal error while selecting the trial data |
| RMXTPP059 |
PP control parameters are not available for plant &1 |
| RMXTPP060 |
&1 is not a workday in plant &2; forward sched. used for production start |
| RMXTPP061 |
Choose a trial |
| RMXTPP062 |
Save the data |
| RMXTPP063 |
Error during processing; see application log |