| Parameter | Reference | Type | Length | Default | Optional | Text |
|---|---|---|---|---|---|---|
| IV_NAMESPACE | TRNSPACE-NAMESPACE | C | 10 | ' ' | X | |
| IV_NAME_TOO_LONG_FOR_OLD | TRPARI-S_CHECKED | C | 1 | ' ' | X | |
| IV_NONSTANDARD_CHARS | TRPARI-S_CHECKED | C | 1 | ' ' | X | |
| IV_REP_CALL | TRPARI-FLAG | C | 1 | ' ' | X | |
| IV_SHOW_ONLY_CHECK_LIKE_INS | TRPARI-FLAG | C | 1 | ' ' | X | General Indicator |
| IV_SUPPRESS_MOD_SHOW | TRPARI-FLAG | C | 1 | ' ' | X | General Indicator |
| IV_WBO_INTERNAL | TRPARI-FLAG | C | 1 | ' ' | X | |
| WI_EXISTENCE_CHECK | TRPARI-S_EXISTS | C | 1 | 'X' | X | X with/ ' ' without existence check |
| WI_MASTERFLAG | TRPARI-W_MASTER | C | 1 | ' ' | X | X - behavior as for DDIC |
| WI_MESSAGE_ENTER_DEVCLASS | TRPARI-W_MSG_DEVC | C | 1 | ' ' | X | Send message 'Maintain development class' |
| WI_NO_DELETE_FUNCTION | TRPARI-W_DEL_TADI | C | 1 | ' ' | X | X - do not offer TADIR deletion function |
| WI_NO_TADIR | TRPARI-W_NO_TADIR | C | 1 | ' ' | X | X - no TADIR exists in the database |
| WI_NO_TDEVC | TRPARI-W_NO_TDEVC | C | 1 | ' ' | X | X - no TDEVC exists in the database |
| WI_READ_ONLY | TRPARI-S_READONLY | C | 1 | ' ' | X | TADIR in display mode |
| WI_TADIR | TADIR | u | 232 | Input string TADIR (database version) | ||
| WI_TDEVC | TDEVC | u | 515 | X | Input string TDEVC (database version) |
| Parameter | Reference | Type | Length | Text |
|---|---|---|---|---|
| EV_EDIT_TASK | E070-TRKORR | C | 20 | possibly edit/share task |
| EV_OBJECT_TRANSPORT | TRPARI-S_CHECKED | C | 1 | X - transport of TT_E071 required |
| EV_TDEVC | TDEVC | u | 515 | new development class (TDEVC) |
| WE_DELETE_TADIR | TRPARI-W_DEL_TADI | C | 1 | Flag for deletion of TADIR entry |
| WE_GENERATED_FLAG_SET | TADIR-GENFLAG | C | 1 | Generated flag set |
| WE_GENERATE_FLAG_REMOVED | TRPARI-W_GEN_FLAG | C | 1 | "Generated object" flag reset |
| WE_REPAIR_FLAG_REMOVED | TRPARI-W_REP_FLG | C | 1 | "Object in repair" flag reset |
| WE_REPAIR_FLAG_SET | TRPARI-W_REP_FLG | C | 1 | "Object in repair" flag set |
| WE_TADIR_NEW | TADIR | u | 232 | New TADIR contentgs |
| WE_TADIR_OLD | TADIR | u | 232 | Old TADIR contents |
| Parameter | Reference | Length | Optional | Text |
|---|---|---|---|---|
| TT_E071 | E071 | 180 | X | Table of objects to be transported |
| Exception | Text |
|---|---|
| CLOSE | Display window closed (continue) |
| DISPLAY_MODE | Only display object |
| EXIT | Function was cancelled |
| GLOBAL_TADIR_INSERT_ERROR | Error occurred inserting into global TADIR |
| NO_MODIFICATION_OF_HEAD_SYST | |
| NO_OBJECT_AUTHORITY | no authorization to execute the function |
| NO_SYSTEMNAME | System name cannot be determined or invalid length |
| NO_SYSTEMTYPE | System type cannot be determined |
| NO_TADIR_TYPE | Object type cannot be included in TADIR |
| OBJECT_RESERVED_FOR_DEVCLASS | |
| OBJ_SPECIFICATION_NOT_UNIQUE | |
| PGMID_OBJECT_NOT_ALLOWED | |
| RESERVED_NAME | Violation of reserved TRESN names |
| TADIR_NOT_EXIST | TADIR does not exist, display not possible |
|
INCLUDE FUNC_STRW_TRINT The function displays the object directory entry (TADIR) for the object given in the WI_TADIR parameter in an online window. The relevantdevelopment class (TDEVC) and statements about local existence aretransferred by the WI_TDEVC, WI_NO_TADIR and WI_NO_TDEVC parameters. Which attributes can be changed, depends on the following factors:
for user DDIC if the parameter WI_MASTERFLAG is set Furthermore, the parameter WI_EXISTENCE_CHECK can be used so that anexistence check takes place. The parameter WI_MESSAGE_ENTER_DEVCLASS generates the message "Enter adevelopment class" on the POPUP. The parameter WI_NO_DELETE_FUNCTION suppresses the delete function. The function returns both the old and new object directory entry(WE_TADIR_OLD, WE_TADIR_NEW) and the new development class (EV_TDEVC). The parameter WE_DELETE_TADIR indicates whether the entry should bedeleted. The parameter WE_GENERATED_FLAG indicates that the generated flag hasbeen set. The parameter WE_GENERATE_FLAG_REMOVED indicates that thegenerated flag has been reset. The parameter WE_REPAIR_FLAG indicates that the repair flag has beenset. The parameter WE_REPAIR_FLAG_REMOVED indicates that the repairflag has been reset. The parameter EV_OBJECT_TRANSPORT indicates whether objects have to betransported, due to changes in the object directory entry. If so, theobjects for transport are transferred with table TT_E071. If componentobjects are already locked, the parameter EV_EDIT_TASK indicates thetask with which the user can edit the object. |
| 1136823 | SOBJ: Display of object directory permits changes |