This enables settings to be changed when the graphic is loaded orreloaded. The parameters of this module are predefined so that only valuesdifferent to the default settings are sent to the graphic. For additional documentation and possible input values, see the fieldin table TBCO having the same name or customizing for the optionprofile. All the parameters marked with 'Identifier' can be activated with '1' =sgrc_const-yes and deactivated with '0' = sgrc_const-no.Description If several charts are overlaid, the columns are automatically expandedin the 'narrower' chart. This switch can be used to find out whichcolumn is expanded. Value range '0' | first column '1' | first column after the fixed left one '2' | column in the middle '3' | last column before the fixed right one '4' | last column Default '3' | last column before the fixed right one Step size for automatic paging in pixel. Allowed entry range: =========================== 000 - 033 Description If this option is set, fast scrolling is deactivated, which might result in undesirable side effects. Value range '0' -> fast scrolling is not active (sgrc_const-no) '1' -> fast scrolling is active (sgrc_const-yes) Default '1' -> fast scrolling is active Flag that determines whether vertical lines, which indicate columnborders in the table section, should be be shown. Values that may be entered: ====================== '0' --> vertical lines are not shown '1' --> vertical lines are shown This flag determines whether objects can be moved in the bar chart. Values that may be entered are: =============================== '0' --> moving is not supported '1' --> moving is supported Value that determines the width of the table area in the bar chartgraphics. This value must be given in 1/10 mm. The width of the table area is non-chart-specific i.e. the same widthin each chart belonging to a bar chart. Range allowed for entries: ========================== 50 - 600 Flag that determines whether changing borders between individual chartsand within a chart is possible between the table and diagram parts. Values that may be entered: ========================== '0' --> Changing areas is not supported '1' --> Changing areas is supported. Flags which determine whether objects in the bar chart can be selected. Values that may be entered are: ============================== '0' --> Selecting is not supported '1' --> Selecting is supported Description Activate/deactivate customize mode If customize mode is activated, you automatically go to the attributesof the corresponding object by double-clicking and you can change themthere. Value range '1' = activate '0' = deactivate Default deactivated Flag that determines whether the bar chart responds to a double click. Valid entries: ========================== '0' --> Double click is not supported '1' --> Double click is supported Flag that determines whether modifying the box contents in the graphictakes place in a window at the level of the toolbar or whether a windowin the corresponding box field is opened to do this. Values that may be entered: =========================== '0' --> Modification window in the toolbar '1' --> Modification window in the corresponding box field. Description Specifies whether the graphics have been converted to the ENJOYinterface. Value range '0' - No ENJOY '1' - Convert background of charts (network and bar chart) '2' - Convert chart, table title and background (bar chart) Default '2' Specifies the scalability of fixed columns as follows: '0' - No scaling '1' - Left fixed columns can be scaled '2' - Right fixed columns can be scaled '3' - Left and right fixed columns can be scaled Specifies that a phantom object cannot be moved over a fixed graphicelement. Specifies the step size for displaying the date when moved. Values that may be entered: ========================== Value|Meaning |Constants in the Include file LBARCCON -----+-----------+-------------------------------------- 1 |Year |BC_CONST-YEAR_UNIT 2 |Quarter |BC_CONST-QUATER_UNIT 3 |Month |BC_CONST-MONTH_UNIT 4 |Week |BC_CONST-WEEK_UNIT 5 |Day |BC_CONST-DAY_UNIT 6 |Hour |BC_CONST-HOUR_UNIT 7 |Minute |BC_CONST-MINUTE_UNIT 8 |Second |BC_CONST-SECOND_UNIT A |application-specific, the value set with 'BARC_ADD_SAPUNIT' is |usedSpecifies when, and in which intervals, a separating line should bedisplayed in the diagram area. Interval that may be entered: 1 .. 20: Display the separating line after the 1- ... nth table row No separating line is displayed for values over 20. Parameter that determines whether the info text for individual objectsis displayed in the bar chart. Valid entries: ========================== '0' --> No information text appears '1' --> Information text appears Description Specifies whether it is an automotive application. Value range '0' --> not an automotive application '1' --> automotive application Default '0' Specifies whether layer-specific information is returned when linking. '0' - link nodes only (AA,AE,EA,EE) '1' - like 0, but the layer is returned as well '2' - start and end determined for each layer, not for each node, otherwise like '1' Default layer type that is used when a layer is added to the bar chart,if no other layer is selected within the bar chart. Permitted entries: ========================== Value|Meaning |Constant in the Include file LBARCCON -----+----------+--------------------------------- 'R' |Rectangle |(BC_CONST-RECTANGLE_LAYER) 'L' |Line |(BC_CONST-SYMBOL_LAYER) 'S' |Symbol |(BC_CONST-LINE_LAYER) Description Color in which selected objects are displayed if color marking isselected. Parameter that defines how the selected objects in the table area areto be represented. Valid values: ====================== 0 --> Framed 1 --> Inverted representation 2 --> Pick representation 3 --> Changed color 4 --> 3D A field that is used as checkbox must be defined for eachchart. Description With this indicator you specify that in the bar chart the icons forChange and Connect overlap, if they are activated. Description '0' - Simultaneous shifting of several nodes not possible (default) '1' - Shifting of several nodes supported. The new positions of the text indexes are reported back. '2' - Shifting of several nodes supported. The position of the mouse cursor is reported back as the position. Specifies whether the background color of a ribbon is handled as aribbon attribute, so that a change in the timescale assistant can besaved as a ribbon attribute. Parameter that specifies the maximum number of errors that will be tolerated. Should more errors occur, for example, when application datais sent to the graphic, the graphic is cancelled. Range of possible entries: ========================== 0 - 100 Parameter that specifies the number of horizontal scroll bars availablein the bar chart graphic. Permitted entry values: ============================== '1' --> Display of a horizontal scroll bar that extends over the entire width of the bar chart graphic. '2' --> Display of two horizontal scroll bars, one for the table area and one for the diagram area. '3' --> Display of a horizontal scroll bar for each table area and one for the diagram area. Description Determines how a selected object within the diagram area should berepresented. Value range '0' Frame '1' Inverted '2' Pick marks '3' Colored marksThe initial mode determines in which mode the bar chart will appearwhen it is first called. Possible entries: ================= '0' --> Selection mode '1' --> Modification mode '2' --> Connecting mode Description Specifies the color of the outline that is depicted when the objects are moved. Description Defines the distance between the upper or lower edge of the graphic element and the corresponding row margin. Value range 0 - 200 in 1/100mm Default 10 Description Time at which scrolling starts when going over edge of chart. Value range 0-3 seconds Default 3 seconds Specifies which objects may be selected. Possible entries: ================= '0'--> No objects '1'--> Objects in the diagram area (nodes) '2'--> Objects in the table area (boxes) '3'--> Objects in the table and diagram area (boxes and nodes) '4'--> Graphic elements Description Specifies whether the phantom object jumps according to the layers whena bar is moved. Description Specifies that the height of the row is automatically set to null ifthe row does not contain any objects. Value range '0' = off '1' = on Default '0' The symbol type determines which symbol will be displayed, when asymbol layer is included in the bar chart. The following list shows all values that may be entered, their meaningand the relevant constants in the LBARCCON Include file. Type|Meaning |(Constants in LBARCCON) ----+------------------------------------------------------------------ 1 |Filled in arrow pointing downwards |(BC_CONST-VC_POINTER_DOWN) 2 |Filled in equilateral triangle pointing downwards |(BC_CONST-VC_TRIANGLE_DOWN) 3 |Arrow pointing to the right (greater than sign) |(BC_CONST-VC_GREATER_SIGN) 4 |Narrow triangle pointing upwards) |(BC_CONST-VC_SLIM_TRIANGLE_UP) 5 |Narrow triangle pointing to the right |(BC_CONST-VC_TRIANGLE_RIGHT) 6 |Narrow triangle pointing to the left |(BC_CONST-VC_TRIANGLE_LEFT) 7 |Rhombus |(BC_CONST-VC_RHOMB) 8 |Two triangles pointing towards each other (fly/hourglass) |(BC_CONST-VC_DOUBLE_TRIANGLE) 9 |Narrow triangle pointing downwards |(BC_CONST-VC_SLIM_TRIANGLE_DOWN) 10 |Square |(BC_CONST-VC_SQUARE) 11 |Circle |(BC_CONST-VC_CIRCLE) 12 |Filled in arrow pointing downwards in circle |(BC_CONST-VC_POINTER_DOWN_IC) 13 |Equilateral triangle pointing downwards in circle |(BC_CONST-VC_TRIANGLE_DOWN_IC) 14 |Arrow pointing to the right (greater than sign) in circle |(BC_CONST-VC_GREATER_SIGN_IC) 15 |Narrow triangle pointing upwards in circle |(BC_CONST-VC_SLIM_TRIANGLE_UP_IC) 16 |Narrow triangle pointing to the right in circle |(BC_CONST-VC_TRIANGLE_RIGHT_IC) 17 |Narrow triangle pointing to the left in circle |(BC_CONST-VC_TRIANGLE_LEFT_IC) 18 |Rhombus in circle |(BC_CONST-VC_RHOMB_IC) 19 |Two triangles pointing towards each other in circle |(BC_CONST-VC_DOUBLE_TRIANGLE_IC) 20 |Narrow triangle pointing downwards in circle |(BC_CONST-VC_SLIM_TRIANGLE_DOWN_IC) 21 |Square in circle |(BC_CONST-VC_SQUARE_IC) Determines whether the start or end date is shown when you change thelength of a graphic element. Time interval after which the graphic sends a signal to ABAP or givesABAP control. The time interval of the timer should be defined in seconds. Permitted entry interval: ==================== 0 - 3600 Description Specifies whether the start times of the sections are modifiable in thetimescale assistant, as well as the start and end times. Value range '0' - not modifiable '1' - modifiable Default '0' Description Controls the active operations in the time scale wizard. Value range '0' - display '1' - insert '2' - change '3' - insert, change '4' - delete '5' - insert, delete '6' - change, delete '7' - insert, change, delete Default '2' Description Specifies whether control should return to ABAP after each change inthe visible section. Value range '0' - off '1' - on Default '0' Position of the graphic window of the bar chart graphic in X directionin %. The lower left corner of the graphic window is used as reference pointto position the graphic window. The value entered here defines the absolute distance between the loweredge of the screen and the left edge of the graphic window. Thisdistance should be defined in percent of the total screen width. Permitted entry interval: =========================== 1 - 100 Width of the graphic window in percent of the screen width. Permitted entry interval: ==================== 1 - 100 Position of the graphic window of the bar chart graphic in Y directionin %. The left lower corner of the graphic window is used as reference pointto position the graphic window. The value entered here defines the absolute distance between the loweredge of the screen and the lower edge of the graphic window. Thisdistance should be defined in percent of the total screen height. Permitted entry interval: ==================== 1 - 100 Height of the graphic window in percent of the screen height. Permitted entry interval: ==================== 1 - 100 |